Partner With Us
+91 9001194777 | +91 8800886359








Younique RADIO FREQUENCY MINI CAUTERY

Availability : In stock
Brand : Younique

R.F. Mini Cautery is a precision dental device for blood vessel and tissue coagulation, enhancing surgical control and patient outcomes.

13,890 15,000 7% off
Free shipping on all orders above ₹ 1500
10 Days Return Policy
View Policy
100% Genuine products

Check Delivery Availability


Write Your Own Review

  • Preparation: Ensure that the Younique R.F. Mini Cautery device and its components, including the handpiece and electrode tips, are properly cleaned, sterilized, and ready for use.
  • Patient Assessment: Assess the patient's dental and medical history and the specific surgical procedure to be performed.Obtain informed consent from the patient, ensuring they are aware of the procedure and potential risks.
  • Handpiece and Electrode Selection: Select the appropriate handpiece for the procedure and securely attach it to the device. Choose the suitable electrode tip based on the surgical needs:Fine tips for precision work on small blood vessels and tissues.Larger tips for broader coagulation.
  • Power and Mode Adjustment: Turn on the Younique R.F. Mini Cautery device and adjust the power settings and coagulation modes according to the specific surgical requirements.Start with lower power levels and increase as needed to achieve effective coagulation.
  • Application of Cautery: Hold the handpiece in a comfortable and stable grip.Gently touch the electrode tip to the target tissue area requiring coagulation or hemostasis.Maintain contact for a brief period, allowing the RF energy to generate controlled heat.Observe the tissue's response, and adjust the power and duration of application as necessary to achieve the desired coagulation effect.Ensure precise control to prevent overheating or collateral damage to surrounding tissues.
  • Hemostasis and Tissue Coagulation: Use the Younique R.F. Mini Cautery to achieve hemostasis by coagulating blood vessels and soft tissues as required during the surgical procedure.Continue this process throughout the surgery to maintain a clear surgical field and prevent bleeding.
  • Monitoring and Evaluation: Continuously monitor the surgical site, assessing the effectiveness of coagulation and tissue response.Adjust the device settings and technique as needed to ensure optimal results.
  • Post-Procedure Care: After completing the surgical procedure, carefully evaluate the surgical site for any residual bleeding.Take necessary steps to address any remaining bleeding or coagulation needs, such as applying pressure or additional cautery as appropriate.
  • Sterilization and Maintenance: After use, follow manufacturer-recommended protocols for cleaning, sterilization, and maintenance of the device, handpiece, and electrode tips.
  • Documentation: Maintain thorough records of the surgical procedure, including details of cautery use, power settings, and any complications or unexpected events.
  • Patient Post-Operative Care: Provide patients with post-operative care instructions, including information on pain management, oral hygiene, and any specific care related to the surgical procedure.

Customer Reviews

Be the first one to review

Packaging
  • 1 x Cautery Machine
  • 1 x Hand Switch Pencil
  • 1 x Hand Switch Pencil Electrodes
  • 1 x Stainless Steel Patient Plate
  • 1 x Patient Plate Cable Cord
  • 1 x Main Cord
  • 1 x Briefcase Bag
Warranty
  • Manufacturer/Importer warranty of 2 year as applicable for this product against manufacturing defect
  • Service and Warranty are handled by the manufacturer/importer directly for this product
  • Oralhealthcart will not be liable to replace the Products and the liability to replace any such Product is that of the Manufacturer/Importer

Suggest Us A Product


Have a product in mind that you'd like to suggest? Click the button below to submit your suggestion.



WhatsApp